HANDHELD MEASURING INSTRUMENTS
298 For product ordering information, see pages 4 10
Model S251C S113C/S331C S114C/S332C
2 to 1600 MHz (S113C) 2 to 1600 MHz (114C)
Frequency range 625 to 2500 MHz
25 to 4000 MHz (S331C) 25 to 4000 MHz (S332C)
Frequency resolution 10 kHz 100 kHz 100 kHz
Frequency accuracy (CW mode) 75 ppm
Display data points Selectable: 130, 259, 517
Immunity to interfering RF signals S251C S113C S331C S114C S332C
On-frequency
3
+10 dBm (RF out), +30 dBc transmission +10 dBm -5 dBm +10 dBm -5 dBm
On-channel
4
+17 dBm +17 dBm +17 dBm +17 dBm +17 dBm
Return loss Range: 0 to 54 dB; Resolution: 0.01 dB
SWR Range: 1 to 65; Resolution:0.01
Cable loss Range: 0 to 20 dB; Resolution: 0.01 dB
Insertion Loss/Gain Display range: –120 to +100 dB
N/A N/A
S251C only Resolution: 0.1 dB
Vertical range
Return loss: 0 to 54 dB
Distance-to-fault SWR: 1 to 65
Horizontal range (meter): 0 to (dp x resolution), where dp = 128, 256 or 512
Horizontal resolution, rectangular windowing resolution (meter): (1.5 x 10
8
) (υp)/ frequency
5
Display range: -80 to +80 dBm, 10 pW to 100 kW
Detector range: -50 to +20 dBm, 10 nW to 100 mW
RF power monitor (Option 5) Offset range: 0 to +60 dB
Resolution: 0.1 dB
Bias Tee (Option 10A) +15 VDC, Surge: 275 mA maximum,
S251C only 25 ms; Steady State: 240 mA maximum
N/A N/A
Spectrum analysis
Frequency range N/A N/A
100 kHz to 1600 MHz (S114C)
100 kHz to 3000 MHz (S332C)
Accuracy N/A N/A ± 2 ppm
Aging N/A N/A ± 1 ppm/yr
Frequency span N/A N/A 0 Hz (zero span), 100 kHz to full span
Resolution bandwidth N/A N/A 10 kHz, 30 kHz, 100 kHz, 1 MHz
Video Bandwidth N/A N/A 100 Hz to 300 kHz in 1-3 sequence
Display datapoint N/A N/A 400
SSB Phase Noise @ (1 GHz)
30 kHz offset
N/A N/A –75 dBc/Hz
Spurious responses (Input related) N/A N/A < –95 dBm
Spurious responses (residual) N/A N/A –45 dBc
Dynamic range N/A N/A 65 dB
Average noise level N/A N/A –97 dBm (full span)
Measurement range N/A N/A +20 dBm to –97 dBm
Display range N/A N/A
2 to 15 dB/div in 1 dB steps,
10 divisions display
Total level accuracy N/A N/A
± 2 dB >300 kHz, typical
± 3 dB <300 kHz, typical
RF input VSWR N/A N/A 2.0:1
Trace memory Up to 200
Instrument configuration
6
10
Test port connector Precision N female
RF OUT test port: RF IN Spectrum Analyzer port:
+22 dBm, 50 , +50 Vdc +20 dBm safe input,
Maximum input RF IN test port: RF power detector: +27 dBm damage level,
+10 dBm, 50 , +50 Vdc +20 dBm, 50 , +50 Vdc Peak Pulse Power +50 Vdc
RF power detector: RF power detector:
+20 dBm, 50 , +50 Vdc +20 dBm, 50 , +50 Vdc
Temperature Operating: 0°C to +50°C
Storage: –20°C to +75°C
Weight 2.18 kg (4.78 lbs.) nominal
Size 25.4 cm x 17.8 cm x 6.1 cm (10 in x 7 in x 2.4 in)
General
Electromagnetic compatibility: Meets European community requirements for CE marking.
RS232: 9 pin D-sub, three wire serial
Specifications
*
1
Site Master is designed for field requirements. Its rugged construction sur-
vives rough field treatment. Battery power, light weight, small size, wide
temperature range, and simple user interface are exactly what field techni-
cians want today. Technicians can test antennas from ground level be-
cause Site Masters distance-to-fault measurement compensates for cable
insertion loss. Furthermore, spectrum analysis, available in certain Site
Master models, allows technicians and field engineers to quickly identify
and solve common RF system problems, such as coverage, interference,
and other path related signal problems. Site Master offers a new and bet-
ter method to install and maintain transmission lines and antennas.
Continued on next page